11
P 52 AUX 3 maximum value (default: 100)
- Sets the level for the Auxiliary output when the MIDI controller source is at its maximum.
Range 0 to +100
A value of 10 is approximately 1 volt – so 100 is approx. 10 volts.
Note that minimum can be set above maximum so that the controller works backwards.
P 53 AUX 3 reset value (default: 0)
Range 0 to 127
- Sets the level the Auxiliary output will reset to when the MODULAR SOLO is powered on or when it
receives a controller reset MIDI command or a new setup is loaded from memory. This is equivalent to
a MIDI message of this value being received, so it will be influenced by min and max settings above.
AUX4 output
P 60 AUX 4 controller number (default: Aftertouch)
- Sets which MIDI controller will control the auxiliary output. The following can be selected:
Off [oFF]
Pitch bend [Pbd]
Velocity [VEL]
Aftertouch [AFt]
MIDI controllers 0-119
P 61 AUX 4 minimum value (default: 0)
- Sets the level for the Auxiliary output when the MIDI controller source is at its minimum.
Range 0 to +100
A value of 10 is approximately 1 volt – so 100 is approx. 10 volts.
Note that minimum can be set above maximum so that the controller works backwards.
P 62 AUX 4 maximum value (default: 100)
- Sets the level for the Auxiliary output when the MIDI controller source is at its maximum.
Range 0 to +100
A value of 10 is approximately 1 volt – so 100 is approx. 10 volts.
Note that minimum can be set above maximum so that the controller works backwards.
P 63 AUX4 reset value (default: 0)
Range 0 to 127
- Sets the level the Auxiliary output will reset to when the MODULAR SOLO is powered on or when it
receives a controller reset MIDI command or a new setup is loaded from memory. This is equivalent to
a MIDI message of this value being received, so it will be influenced by min and max settings above.
CLOCK1 output
P 70 Clock1 type (default: clock normal)
- Sets which MIDI controller will control AUX2 output. The following controllers can be selected:
Clock normal [cLn]
Clock inverted [cLi]
Stop/start normal [SSn]
Stop/start inverted [SSi]
The ON voltage can be set using parameter 73 – clock1 voltage.
Inverted settings mean that on is zero and off is high. (like s-trig).
Comentários a estes Manuais